| Model |
P3251 |
Option |
| Pressure type |
Negative or positive gauge pressure |
absolute pressure |
Negative or positive gauge pressure |
| Output signal |
4 . . . 20 mA - 2-wire system 0 . . . 5 VDC - 3-wire system 0 . . . 10 VDC - 3-wire system |
other signals on request |
| Accuracy % of F. S. 1) |
0,5 |
0,25 |
0,5 |
0,25 |
0,5 |
0,25 |
|
| Ranges accord. to EN |
0 . . . 0.1 bar 2) to 0 . . . 16 bar
|
0 . . . 25 bar to 0 . . . 600 bar
|
0 . . . 0,25 bar to 0 . . . 16 bar |
|
| Sensor element |
piezoresistive |
thin film |
piezoresistive |
|
| Repeatability |
≤± 0.05% of F. S. |
|
| Stability (annual) |
≤± 0.2% of F. S. in rated conditions |
|
| Case |
Stainless steel |
|
| Pressure connection |
≤ 0…1,6 bar G 1 B;≥0...2,5 bar G 1/2 B |
|
| Wetted parts |
Stainless steel |
|
| Overload limit |
≤16 bar 3,5 x; ≤600 bar 2 x; |
|
| Electrical connection |
plug according to DIN EN 175301-803 form A with junction box round connector M12x1; 4-pin
|
cable outlet with 1 m cable |
| Power supply |
10 . . . 30 VDC (14 . . . 30 VDC for output 0 . . . 10 V) |
|
| Power consumption |
output 4 . . . 20 mA: signal currency voltage output: 8 mA |
|
| Load |
≤ UB-12V/0.020A for output (0) 4 . . . 20 mA > 5 kOhm for output 0 . . . 5 V > 10 kOhm for output 0 . . . 10 V |
|
| Temp. compens. range |
0 . . . 80 °C |
|
Temperature influence - Zero point - Measuring range |
± 0.2% / 10 K 3) ± 0.2% / 10 K |
|
| Adjustability |
zero point and full scale up to ± 10% |
|
| Response time |
≤1 ms (within 10% to 90% of F. S.) |
|
| Protection type |
IP 65 to EN 60 529 / IEC 529 |
IP 67 for cable outlet |
| Emission 4) |
according to EN 61 326 |
|
| Interference 4) |
according to EN 61 326 |
|
| Electrical protection types |
polarity, overload and short-circuit protection |
|
Temperature ranges - Storage - Medium - Ambient |
-40 . . .100 °C -30 . . .100 °C -20 . . . 80 °C |
medium temperature -40 . . . 125 °C
integrated cooling element for temperatures up to 150° C |
| Weight |
approx. 0.2 kg |
|